Installing EMU Microcode

Prerequisites

Preliminary Procedure

C–2 UltraSCSI RAID Enclosure
The following items are required to upgrade the EMU microcode
using the EMU UART connector:
EMU microcode file (for example, FLSH_011.HEX)
PC
Communications program, such as PROCOMM PLUS
Compaq adapter cable, part number 17–04697–01, with the
following connectors:
— 9-pin RS232
— 8-pin RJ45
Complete the procedure in Table C–1 prior to starting the installation
procedure.
Table C–1 Preliminary Procedures
1.
Shut down the software for each controller and eject its personal
computer memory card industry association (PCMCIA) card.
2.
Connect the 9-pin RS232 connector to a PC COM port connector.
3.
Connect the 8-pin RJ45 connector to the master EMU center UART
connector.
4.
Configure the communications software parameters as follows:
Parameter
Baud rate
Data bits
Parity
Stop bits
Protocol
CR/LR conversion
XON/XOFF
Connection
Flow control
Value
38,400 Baud
8
None
1
Raw ASCII
None
None
Direct (no modem)
None