Environmental Monitoring Unit
3–16 UltraSCSI RAID Enclosure
The error condition still exists after 1 hour has passed. This
situation causes the audible alarm to continue sounding once
every hour for approximately 5 seconds.
To clear all the fault code displays, press and hold the alarm control
switch for at least 5 seconds.
The alarm control switch does not affect either the error
condition or the error condition code stored by the EMU.
The only way to clear a stored error condition code is to
correct the problem.
If the enclosure is in standby power mode, the alarm control switch
functions as an enclosure power switch. Press the alarm control
switch on each enclosure to restore dc power to the enclosure.

EMU Status LEDs

Table 3–5 shows the three indications possible for EMU status LEDs.
If an LED's blinking or flashing interval is more than 1 second, the
LED is considered O
.
N
Table 3–5
Subsystem Status LEDs Displays
Symbol
LED is O
LED is F
once per second).
LED is O
second).
Note
Condition
.
FF
(blinking rapidly—blinks more than
LASHING
or blinking slowly (blinks less than once per
N