Firmware Updating With Usb Device - Oki MB760 Service Manual

Hide thumbs Also See for MB760:
Table of Contents

Advertisement

8.2

Firmware Updating with USB Device

To update firmware, store update program and firmware data files in the USB device.
The update program is "signatures.sig", and it needs to be stored in the USB device. It is
necessary for updating firmware except that of the System firmware.
For the data file for each firmware, refer to the following tables.
Notes:
When performing the update, use the latest program.
8.2.1
Firmware type and data file name for updating
Equipment
Firmware
System firmware System control PC board
PU firmware
SU firmware
System software
Store the data file for updating in the model specific folder. This configuration is an example. The
number of files differs depending on the installed option.
Model specific folder name
Notes:
• Since the date and time set in the equipment are recorded in the firmware update log, make
sure that they are correct before updating the firmware.
• Never change the model specific folder name, since it is used for identifying the data file
when the data files used for updating multiple models are stored in the USB device.
45641001TH Rev.1
Stored
(SYS board)
PU PC board
SU PC board
HDD
N29800_01
USB device
N29800_01
Fig.8-4
Data file name
O290SF0Wxxxx.tar
* xxxx is version.
H291PUPWW.xxxx
* xxx is version.
H282SUPWW.xxxx
* xxx is version.
O290HD0Wxxxx.tar
* xxxx is version.
O290SF0Wxxxx.tar
H291PUPWW.0015
H282SUPWW.xxxx
O290HD0Wxxxx.tar
signatures.sig
version
Oki Data CONFIDENTIAL
Display
SYSTEM FIRMWARE
(OS Data)
ENGINE FIRMWARE
SCANNER FIRMWARE
SYSTEM SOFTWARE
(HD Data)
8-3 /