Oki MB760 Service Manual page 167

Hide thumbs Also See for MB760:
Table of Contents

Advertisement

[501B] No URL (host/port) or invalid path
Classification
Communication error with
external application
Check item
Setting
[5030] HTTP communication error
Classification
Communication error with
external application
Check item
Setting
[50FF] eBR2 internal error
Classification
MFP internal error
Check item
Setting
[5110] Toner cartridge detection error
Classification
Web Page related error
Check item
Setting
[5212] Time for cleaning of the slit glass and main charger
Classification
Web Page related error
Check item
Setting
45641001TH Rev.1
Initial URL is invalid.
Set the correct initial URL.
An error in the HTTP communication
Check the URL for communication.
Check that the valid IP address is assigned to connect to the server.
A fatal error occurred in the MFP
Restart the MFP, and then try again.
• Check if the toner cartridge is installed properly.
• Check if the toner cartridge detection sensor operates properly.
• Clean the LED head and main charger.
• If the message is not cleared after the cleaning, check if there is any
detection error, breakage or poor connection of the needle electrode
cleaner detection sensor.
Oki Data CONFIDENTIAL
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures