Web Page Related Error/Communication Error With External Application - Oki MB760 Service Manual

Hide thumbs Also See for MB760:
Table of Contents

Advertisement

5.2.5

Web Page related error/Communication error with external application

Message displayed in the
Error code
5010
-
5012
Invalid temporary password
and permanent password
5013
e-Bridge communication
error
5014
No SSL certificate
5015
Invalid SSL certificate
5016
Expired SSL
certificateIncorrect time in
MFP
5017
Other SSL certificate related
error
5018
Invalid DNS error
5019
Connection error
501A
Proxy error
501B
No URL (host/port) or invalid
path
5030
HTTP communication error
50FF
eBR2 internal error
5110
Toner Not Recognized -
Please Check Toner.
5212
Time for Slit Glass and Main
Charger Cleaning - Please
Clean Slit Glass and Main
Charger.
5BD0
Power failure occurred
during restore
5C10
FAX Unit is not attached.
5C11
Security error on Address
Book.
45641001TH Rev.1
Web Page screen
Internal setting error: There is a print job,
a proof print job, a private print job, a
print job without a set department code,
a scan job or a fax job remaining in this
equipment.
Authentication error: A temporary
password downloaded from e- Bridge
and entered in this equipment is not
valid, or the permanent password set in
the e- Bridge is not valid.
e-Bridge communication error:
Communication is attempted while the
e-Bridge is enabled for some reason
such as version upgrade.
No SSL certificate: There is no SSL
certificate or the certificate is not in a
correct file format.
Invalid SSL certificate: SSL certificate is
not valid.
Expired SSL certificate: SSL certificate
is expired.
Other SSL certificate related error: SSL
certificate is invalid.
Invalid DNS error: DNS address is
invalid.
Connection error: Settings for initial URL
and proxy are incorrect.
Proxy error: IP address or port for proxy
setting is invalid.
No URL (host/port) or invalid path: Initial
URL is invalid.
An error in the HTTP communication
A fatal error occurred in the MFP
Toner cartridge detection error.
Appears when the time for main charger
cleaning comes (at every output of
approx. 10,000 sheets)
Power supply is cut off during the
restoration of database sent from Web
Page
Network FAX is disabled because the
FAX Unit is not attached
The network FAX job failed because the
specified address is not registered in the
Address Book
Contents
Oki Data CONFIDENTIAL
Troubleshooting
P. 5-82
P. 5-82
P. 5-82
P. 5-82
P. 5-82
P. 5-83
P. 5-83
P. 5-83
P. 5-83
P. 5-83
P. 5-84
P. 5-84
P. 5-84
P. 5-84
P. 5-84
P. 5-85
P. 5-85
P. 5-85
5-19 /