[2D67] FTP service not available
Check if the setting of FTP service is valid.
[2D68] File sharing service not available
Check if the setting of SMB is valid.
[2D69] NetWare service not available
Check if the Netware setting is enabled.
[2DC1] Power failure
Check if the power cable is connected properly and it is inserted securely.
Check if the power voltage is unstable.
[2e10] UsB storage system access abnormality
Turn the power OFF and then back ON. Perform the job in error again. If the error still occurs,
first, check if there are no jobs existing and then perform HDD formatting ([5] + [C] + [POWER]
ON → [3] → [1]).
[2e11] Insufficient memory capacity for UsB storage
If there is a job in progress, perform the job in error again after the job in progress is finished.
If the error still occurs, turn the power OFF and then back ON, and then perform the job in
error again.
[2e12] message reception error in UsB storage
[2e13] message transmission error in UsB storage
Turn the power OFF and then back ON. Perform the job in error again.
[2e14] Invalid parameter for UsB storage
If a template is being used, recreate the template. If the error still occurs, turn the power OFF
and then back ON. Perform the job in error again.
[2e15] exceeding maximum file capacity
Delete some files in the folder. Perform the job in error again.
[2e30] Directory creation failure in UsB storage
Check if access privilege to the storage directory is writable. Check if the server or local disk
has sufficient space in its disk capacity.
[2e31] File creation failure in UsB storage
Check if access privilege to the storage directory is writable. Check if the server or local disk
has sufficient space in its disk capacity.
[2e32] File deletion failure in UsB storage
Turn the power OFF and then back ON. Perform the job in error again. If the error still occurs,
first, check if there are no jobs existing and then perform HDD formatting ([5] + [C] + [POWER]
ON → [3] → [1]).
[2e33] File access failure in UsB storage
Check if access privilege to the storage directory is writable. Check if the server or local disk
has sufficient space in its disk capacity.
45641001TH Rev.1