16.6 Double Serial
Interface Board, cont.
Intermec EasyCoder 501 XP – Service Manual Ed. 4
Connector Confi guration
The serial interface "uart3:" has a DB-25pin male connector.
Pin
Signal Name
1
2
TxD
3
RxD
4
RTS
5
CTS
6
DSR
7
GND
8
9
+20M1
10
-20M1
11
+TXD
12
-TXD
13
+20M2
14
-20M2
15
+RS422I
16
+5V
17
-RS422I
18
+RxD
19
+RS422O
20
DTR
21
-RS422O
22
RI
23
Shield
24
25
-RxD
1
/. The external 5V is automatically switched off at overload.
Chapter 16 Interfaces
Description
Not connected
RS-232 Transmitter
RS-232 Receiver
RS-232 Request To Send
RS-232 Clear To Send
RS-232 Data Set Ready
Ground
Not connected
+20 mA current loop
-20 mA current loop
+TXD 20 mA current loop
-TXD 20 mA current loop
+20 mA current loop (printer active receiver)
-20 mA current loop (printer active receiver)
+RS-422 Receive
5 Volt for external use (max. 200 mA)
-RS-422 Receive
+TXD 20 mA current loop
+RS-422 Transmit
RS-232 Data Terminal Ready
-RS-422 Transmit
RS-232 Ring Indicator
Optional shield for RS 422
Not connected
-TXD 20 mA current loop