Test Points - Intermec EasyCoder 501 XP Service Manual

Bar code label printer
Hide thumbs Also See for EasyCoder 501 XP:
Table of Contents

Advertisement

15.5 Test Points

P35
IC305
P32
IC304
Intermec EasyCoder 501 XP – Service Manual Ed. 4
The CPU board is provided with test points that allow all currents
from the power supply to be tested.
P24
P84
Test Points
GND
V 5.3
V 5.0
RESET High level = active printer
V24
P24
V40
POWER
V40
VCC
5.3V
P83
Ground
Feed voltage for V5.0, approx. 5.3V
Logic power, 5V ± 5%
Feed voltage for P24, 24V ±5%
Printhead and cutter voltage, approx. 24V when active
Feed voltage for stepper motors, 42V ±10%
Chapter 15 CPU Board
GND
IC11
/RESET
KEYB.
101