Access Level Control Of Configuration Parameters - Panasonic KX-UTG200 Setup Manual

Hide thumbs Also See for KX-UTG200:
Table of Contents

Advertisement

Example of the NOTIFY message sent from the SIP server:
NOTIFY sip:1234567890@sip.example.com SIP/2.0
Via: SIP/2.0/UDP xxx.xxx.xxx.xxx:5060;branch=abcdef-ghijkl
From: sip:prov@sip.example.com
To: sip:1234567890@sip.example.com
Date: Thu, 1 Jan 2014 01:01:01 GMT
Call-ID: 123456-12345678912345678
CSeq: 1 NOTIFY
Contact: sip:xxx.xxx.xxx.xxx:5060
Event: check-sync
Content-Length: 0
For more information about the related parameters
CFG_CYCLIC (Page 257)
CFG_CYCLIC_INTVL (Page 258)
CFG_RESYNC_TIME (Page 258)
CFG_RESYNC_FROM_SIP (Page 258)

2.4.6 Access Level Control of Configuration Parameters

Access level control of configuration parameters provides a flexible mechanism to control the user level at
which each configuration parameter can be imported or exported.
An "access" attribute can be added to each parameter to control the access level in the provision configuration
file. The value range for access levels includes "A" (Administrator) and "U" (User). These access levels can
be assigned individually or together.
For example: access="A", access="U", and access="AU"
Available settings in the web user interface and phone user interface depend
on the access level configuration
Configuration parameters designed for use with the web user interface and phone user
interface:
Configuration parameters that have been designed for use with the web user interface and phone user interface
configuration are available depending on the access level control configured in provisioning.
For example:
"ADMIN_PASS" is designed for use with the web user interface. If it is configured with only Administrator
account access, it will only be available for Administrator users when they log in to the web user interface after
provisioning is performed. "ADMIN_PASS" will not be available for User accounts.
Configuration parameters not designed for use with the web user interface and phone user
interface:
Configuration parameters that have not been designed for use with the web user interface and phone user
interface configuration will not be available regardless of the access level configured in provisioning.
Importing and exporting with the web user interface
When importing or exporting provision configuration parameters, only parameters configurable for the logged
in user level can be imported or exported.
When importing or exporting web configuration parameters, only parameters configurable and available for
the logged in user level can be imported or exported.