Advertisement

5. PROGRAMMING

5.4.7 Configuring Soak Test Mode

This option enables you to enter device zones into Soak Test mode.
To Enable the Soak Test proceed as follows:
Step 1
Select "ADD TO
[1]
SOAK TEST" Option
02:ZONES/DEVICES
ADD TO SOAK TEST
– Enabling Soak Test mode
[1]
Enter the Installer Menu, select the "02.ZONES/DEVICES" option (see section 5.2) and then select the "ADD TO
SOAK TEST" option.
[2]
Select the respective Group of the device you wish to add the Soak Test. For example, "MOTION SENSORS".
[3]
Scroll to select the specific device zone number.
[4]
Select between "Disable test" (default) or "Enable test".
[5]
If set to "Enable Test" you must set the duration of the Soak Test before the Soak Test will start (see Section
5.5.8). You can stop the test for the relevant zone by changing the setting to "Disable test" at any time during the
testing period.
All Soak test zones will be reset to start a new test upon occurrence of one of the following: 1)
Power up of the system;

5.4.8 Updating Devices after Exiting Installer Mode

When exiting the "Installer mode", the PowerMaster panel communicates with all devices in the system and updates
them with the changes that have been performed in their "Device Settings" configuration. During the updating period,
the display indicates "DEV UPDATING 018" where the number (for example, 018) is a countdown of the remaining
number of devices yet to be updated.

5.5 Control Panel

General Guidance – "Control Panel" Flow-Chart & Menu Options
5.5.1
The "CONTROL PANEL" menu enables you to configure and customize the operation of the control panel. The
"CONTROL PANEL" menu provides you with configurable parameters divided into several groups, each dealing with
certain aspects of the system operations as follows (see detailed list in Step 2 of the chart below):
Group
Description of Group Features and Parameters
Arming/Disarming
Contains configurable features and parameters related to Arming and Disarming of the
and Exit/Entry
system and the Exit and Entry procedures.
Procedures
Zone Behavior
Contains configurable features and parameters related to the functionality of the Zones.
Alarms &
Contains configurable features and parameters related to initiating, canceling and
Troubles
reporting of Alarm and Trouble events.
Sirens
Contains configurable features and parameters common to all sirens in the system.
User Interface
Contains configurable features and parameters related to the functionality of the panel's
audible and visual indications.
Jamming &
Contains configurable features and parameters related to detecting and reporting of RF
Supervision
Jamming and device Supervision (missing device) events.
Miscellaneous
Contains a variety of other configurable features and parameters related to the system.
1
Soak Test is not applicable for UL installations.
36
1
Step 2
Select the respective
[2]
device Group
CONTACT SENSORS
MOTION SENSORS
2)
Setup of Factory Default;
Step 3
Select device zone
[3]
number
Z09:Motion Sens
ID No. 120-2468
3)
Change in system Soak
D-304762 PowerMaster-10/30 G2 Installer's Guide
Step 4
Select to enable or
[4]
disable the Soak Test
Disable test
Enable test
Time.
Step 5
[5]
See
[5]
to
Step 3
Section
5.5.2
5.5.3
5.5.4
5.5.5
5.5.6
5.5.7
5.5.8