Replacing A Device; Configuring Soak Test Mode - Visonic PowerMaster 360 Installer's Manual

Table of Contents

Advertisement

4. PROGRAMMING

4.4.5 Replacing a Device

Use this option to replace a faulty device that is enrolled in the system with another device of the same type number
(i.e. same first 3 digit of the ID number – see section 4.4.2.A) while keeping the same configuration of the original
device. There is no need to delete the faulty device or to reconfigure the new device. Once enrolled, the new device will
be configured automatically to the same configuration of the faulty (replaced) device.
To Replace, a device proceed as follows:
Step 1
Select "REPLACE
[1]
DEVICES" Option
02:ZONES/DEVICES
REPLACE DEVICES
– Replacing a Device
[1]
Enter the Installer Mode menu, select the "02:ZONES/DEVICES" option (see section 4.2) and then select the
"REPLACE DEVICES" option.
[2]
Select the respective group of the device you wish to replace. For example, "KEYFOBS".
[3]
Scroll the Device Group, identify (by zone and/or ID number) the exact device you wish to replace, for example:
"K03: Keyfob > ID No. 300-0307".
If you try enrolling a new device of a different type than the replaced device, the PowerMaster 360 will reject the
new device and the Virtual Keypad display will read "WRONG DEV.TYPE".
When done, the Virtual Keypad display shows the device details of the new device.

4.4.6 Configuring Soak Test Mode

This option enables you to enter device zones into Soak Test mode.
To Enable the Soak Test proceed as follows:
Step 1
Select "ADD TO
[1]
SOAK TEST" Option
02:ZONES/DEVICES
ADD TO SOAK TEST
– Enabling Soak Test mode
Enter the Installer Mode menu, select the "02.ZONES/DEVICES" option (see section 4.2) and then select the "ADD
[1]
TO SOAK TEST" option.
Select the respective Group of the device you wish to add the Soak Test. For example, "MOTION SENSORS".
[2]
[3]
Scroll to select the specific device zone number.
[4]
Select between "Disable test" (default) or "Enable test".
If set to "Enable Test" you must set the duration of the Soak Test before the Soak Test will start (see section
[5]
4.5.8). You can stop the test for the relevant zone by changing the setting to "Disable test" at any time during the
testing period.
All Soak test zones will be reset to start a new test upon occurrence of one of the following:
1) Power up of the system;
22
Step 2
Select the respective
[2]
device Group
CONTACT SENSORS
KEYFOBS
Step 2
Select the respective
[2]
device Group
CONTACT SENSORS
MOTION SENSORS
2)
Setup of Factory Default;
Step 3
Select exact device
[3]
you wish to replace
K03:Keyfob
ID No. 300-0307
Step 3
Select device zone
[3]
number
Z09:Motion Sens
ID No. 120-2468
3)
Change in system Soak
D-305735 PowerMaster 360 Installer's Guide
Step 4
Enroll the new device
[4]
ENROLL NOW or
ENTR ID:300-XXXX
Step 4
Select to enable or
[4]
disable the Soak Test
Disable test
Enable test
Time.
Step 5
See 
[4].
Step 5
[5]
See 
[5]
 to
Step 3