Local Diagnostics Test; Installation; General Guidance (See Fig. 4) - Visonic KF-234 PG2 Accessories Manual

Powermaster-10 accessories
Hide thumbs Also See for KF-234 PG2:
Table of Contents

Advertisement

5. LOCAL DIAGNOSTICS TEST

A. Separate the base from the cover (see Fig. 5).
B. Put back the cover to return the tamper switch to its normal (undisturbed) position, and then secure the front
cover to the base with the case closure screw.
C. Walk-test the coverage area - see Fig. 2. Walk across the far end of coverage pattern in both directions, The
red LED lights each time your motion is detected followed by 3 LED blinks.
The following table indicates received signal strength indication.

6. INSTALLATION

6.1 General Guidance (see fig. 4)

D-302758
LED response
Green LED blinks
Orange LED blinks
Red LED blinks
No blinks
IMPORTANT!
reception must be assured.
Therefore,
"poor"
strength is not acceptable. If
you receive a "poor" signal from
the detector, re-locate it and re-
test until a "good" or "strong"
signal strength is received.
Diagnostics
Note: For detailed
Test
instructions
refer
PowerMaster-10 Installer Guide.
1. Keep away from heat
sources.
2. Do not expose to air
drafts.
3. Do not install outdoors.
4. Avoid direct sunshine.
NEXT PG2, NEXT-K9 PG2
Reception
Strong
No communication
Reliable
signal
EVENT
1
2
LED
to
ENROLL
button
Figure 3. Device enroll
5. Keep wiring away from
power cables.
6. Do not install behind
partitions.
7. Mount on solid stable
surface.
Good
Poor
Rx Tx
button
9