4.9 DEFINE CUSTOM

This mode allows you to define up to 5 zones names (in addition to the zone names that can be defined in the DEFINE ZONES
mode - see par. 4.3).
(see figure 4.1a)
9. DEFINE CUSTOM
I
OK
CUST. ZONES NAME
<OK> TO EXIT

4.10 DIAGNOSTIC TEST

This mode allows you to test the function of all protected area
wireless sensors / wireless sirens / wireless keypads and to
receive / review information regarding the received signal
strength. Three reception levels are sensed and reported:
Received Signal Strength Indication:
Reception
Buzzer Response
Strong
Happy Tune twice ( - - - –––– ) ( - - - ––––)
Good
Happy Tune ( - - - –––– )
Poor
Sad tune ( –––––––– )
The diagnostic test process is shown in figure 4.10.
The following GSM/ GPRS messages are reported:
Message
Description
Unit is OK
GSM / GPRS functioning properly.
GSM comm.
The GSM/GPRS module does not
loss
communicate with the Panel
Pin code fail
Missing or wrong PIN code.
(Only if SIM card PIN code is enabled.)
GSM net. fail
Unit failed with registration to local
GSM network.
SIM card fail
SIM not installed or SIM card failure.
GSM not
GSM auto enroll failed to detect
detected
GSM/GPRS module.
No GPRS
The SIM card does not have the GPRS
service
service enabled.
GPRS conn.
Local GPRS network is not available
fail
or, wrong setting to GPRS APN, user
and/or password.
Srvr
VDNS Receiver cannot be reached –
unavailable
Check the Server IP
IP not defined
Server IP #1 and #2 are not configured.
APN not
APN is not configured.
defined
SIM card
After entering a wrong PIN code 3
locked
consecutive times the SIM is locked.
To unlock it enter a PUK number. The
PUK number cannot be entered by the
PowerMax Pro.
Denied by
The
server
request.
registered on the VDNS Receiver.
24
EDIT USER TERM 1
EDIT USER TERM 2
I
OK
To edit User Terms, use the following buttons on the control panel keypad:
press
press
Figure 4.9 – Define Custom
VDNS
denies
the
Check
that
the
EDIT USER TERM 3
to scroll backward; press
to change from small caps to big caps ; press
When you are instructed to perform "walk test", walk
throughout the site to check the detectors / sensors. When
a detector/sensor is triggered into alarm, its name, number
and the alarm reception level should be indicated (for
example, "Bathroom", "Z19 strong") and the buzzer should
sound according to the alarm reception level (1 of 3).
IMPORTANT! Reliable reception must be assured. Therefore,
a "poor" signal strength is not acceptable. If you get a
"poor" signal from a certain detector, re-locate it and re-test
until a "good" or "strong" signal strength is received. This
principle should be followed during the initial testing and also
throughout subsequent system maintenance.
connection
Panel
is
EDIT USER TERM 4
EDIT USER TERM 5
to scroll forward ;
for space