APPENDIX A. Specifications

APPENDIX A. Specifications

A1. Functional

PowerMaster-10 G2
Zones Number
30 wireless zones (including 1 hard-wired
input).
Hard-wired Zone
2.2 kΩ E.O.L. resistance (max. resistance of
Requirements
wires 220 Ω).
Maximum Loop
1.5 mA
Current
Maximum Loop
3.3 V
Voltage
Loop Shorted
0.00 – 1.47 V (0.00 – 1.76 K )
Loop Normal
1.47 – 1.80 V (1.76-2.64 K )
Loop Tampered
1.80 – 2.03 V (2.64-3.52 K )
Loop Alarm
2.03 – 2.33 V (3.52-5.26 K )
Loop Open
2.33 – 3.30 V (5.26 - ∞
Installer and User
Codes
* Codes must not be identical
Control Facilities
-
-
Note: For SIA CP-01 compliance, when using
KF-234 PG2 an external siren must also be
used. CP-01 features not to be enabled in UL
Listed product.
Display
Single line, backlit 16-large character LCD.
Arming Modes
AWAY, HOME, AWAY-INSTANT, HOME-
INSTANT, LATCHKEY, FORCED, BYPASS.
Note: AWAY-INSTANT and HOME-INSTANT
are not permissible for CP-01 installations.
Alarm Types
Silent, personal panic/emergency, burglary,
gas (CO), and fire.
Siren Signals
Continuous (intrusion / 24 hours / panic); triple
pulse – short pause - triple pulse... (fire);
four pulses – long pause – four pulses... (gas);
long pulse – long pause – long pulse... (flood).
Siren (bell) Timeout
Programmable (4 min. by default)
Internal Sounder
At least 85 dBA at 10 ft (3 m)
Output
Supervision
Programmable time frame for inactivity alert
Special Functions
- Chime zones
- Diagnostic test and event log.
- Local and Remote Programming over
- Calling for help by using an emergency
- Tracking inactivity of elderly, physically
Note: Tracking inactivity of elderly not to be
enabled in UL Listed product.
Data Retrieval
Alarm memory, trouble, event log
74
)
1 master installer (9999 by default)*
1 installer (8888 by default)*
1 master user, no. 1 (1111 by default)
Users nos. 2 - 8
Integral keypad, wireless keyfobs and
keypads
SMS commands via optional GSM/GPRS
module.
Remote control by telephone.
Telephone, GSM /GPRS connections.
transmitter.
handicapped and infirm people.
PowerMaster-30 G2
Up to 64 wireless zones, (including 2 hard-
wired inputs).
2.2 kΩ E.O.L. resistance (max. resistance of
wires 220 Ω).
1.5 mA
3.3 V
0.00 – 1.47 V (0.00 – 1.76K )
1.47 – 1.80 V (1.76 – 2.64 K )
1.80 – 2.03 V (2.64 – 3.52 K )
2.03 – 2.33 V (3.52 – 5.26 K )
2.33 – 3.30 V (5.26 – ∞
1 master installer (9999 by default)*
1 installer (8888 by default)*
1 master user, no. 1 (1111 by default)
Users nos. 2 - 48
* Codes must not be identical
-
Integral keypad, wireless keyfobs and
keypads
-
SMS commands via optional GSM/GPRS
module.
-
Remote control by telephone.
Note: For SIA CP-01 compliance, when using
KF-234 PG2 an external siren must also be
used. CP-01 features not to be enabled in UL
Listed product.
Single line, backlit 16-large character LCD.
AWAY, HOME, AWAY-INSTANT, HOME-
INSTANT, LATCHKEY, FORCED, BYPASS.
Note: AWAY-INSTANT and HOME-INSTANT
are not permissible for CP-01 installations.
Silent, personal panic/emergency, burglary,
gas (CO), and fire.
Continuous (intrusion / 24 hours / panic); triple
pulse – short pause - triple pulse... (fire);
four pulses – long pause – four pulses... (gas);
long pulse – long pause – long pulse... (flood).
Programmable (4 min. by default)
At least 85 dBA at 10 ft (3 m)
Programmable time frame for inactivity alert
- Chime zones
- Diagnostic test and event log.
- Local and Remote Programming over
Telephone, GSM /GPRS connections.
- Calling for help by using an emergency
transmitter.
- Tracking inactivity of elderly, physically
handicapped and infirm people.
- Message center (recording and playback)
- Two-way voice communication
Note: Tracking inactivity of elderly not to be
enabled in UL Listed product.
Alarm memory, trouble, event log
D-304762 PowerMaster-10/30 G2 Installer's Guide
)