Reporting Messages To A Pager; Conducting A Walk Test - Visonic PowerMaxComplete User Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaxComplete:
Table of Contents

Advertisement

SPECIAL FUNCTIONS

Reporting Messages to a Pager

Control
panel
Since the PowerMaxComplete can be programmed
to report events to a pager, the user of the pager
must be informed on how to interpret the numerical
message that his pager displays.
Communication with a pager takes place as follows:
The PowerMaxComplete dials the pager's
phone number, waits 5 seconds and sends the
numerical message.
The
message
transmitted
PowerMaxComplete to the pager is actually a
string of digits, as follows:
[XXXXXXXXXXXXXXXX]
Pager's PIN No. - Up to 16 digits
Programmed by the Installer
Figure 6. Pager Message Structure
The person receiving the message sees only the
"YYY -0ZZ#" part of the message, which he can
interpret by using the following legend:
Events types (YYY) are coded as follows:
Event
Code
Event
Alarm
919
Fire
Trouble
818
Close
Emergency 717
Open
Panic
616
Latchkey 103
ZZ is the zone number in which the event occurred,
or the user number in case of Close, Open and
Latchkey events.
Example 1: Message reads "919-003":
This means an alarm occurred in Zone No. 3.
Example 2: Message reads "101-008":
This means the system was closed (armed) by user
No. 8.

Conducting a Walk Test

The walk test is an indispensable operation by which
you verify that all detectors function properly, without
disturbing the neighbors with loud sirens. The test
must be performed at least once a week, and
should include all detectors in all zones.
Before performing walk test, all the detectors must
be in normal state. Normal state is achieved when no
motion is made for at least 2 minutes.
Note: During the test period, 24-hour zones will not
cause an alarm if violated, but a fire zone will
function normally.
20
A typical test will take place as follows:
A. Press the test button
Pager
M
B. The display will prompt you for your user code:
C. Enter your code. The siren will sound for 2
seconds and the display will change to:
D. Walk throughout the protected area and make
sure you trigger every detector with no exception
(move across the field of view of motion
detectors and open/close doors and windows).
by
the
Each time a detector is triggered:
[YYY]
[0ZZ#]
Event
Zone or
EXAMPLE 1: You triggered a motion detector in
Type
User No.
the living room (zone 11). The display will show:
Code
EXAMPLE 2: You opened a window in the guest
515
room (zone 13). The display will show:
101
102
E. When done, click the
repeatedly. The display will show the test results,
zone after zone, in ascending numerical order. For
example:
F. To resume testing, click
mode, click
G. Click
normal state.
.
ENTER CODE
_ _ _ _
TESTING
The "Happy Tune" will sound,
The zone name and number will be displayed
briefly,
LIVING ROOM
Z11 VIOLATED
After 5 seconds the display will revert to:
TESTING
GUEST ROOM
3
Z1
OPEN
After 5 seconds the display will revert to:
TESTING
GUEST ROOM
(alternating)
Z13 OK
or: "Z13 NOT OK" if there was no response
from Z13.
. To quit the test
. The display will then read:
<OK> TO EXIT
. The display will revert to its
button
D-300886

Advertisement

Table of Contents
loading

Table of Contents