5. PROGRAMMING
45:STROBE TIME
46:SIREN ON LINE
5.5.6 Configuring Audible & Visual User Interface
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 5.5.1.
Option
51:PIEZO BEEPS
With Partition disabled
51:PIEZO BEEPS
With Partition enabled
52:TROUBLE BEEPS
53:MEMORY PROMPT
54:LOW-BAT ACK
55:BACK LIGHT
42
Define the length of time the strobe light will flash upon alarm.
Options: 5/10/20 (default)/40/60 minutes
Determine if the siren will be activated when the phone line fails and the system is armed.
Options: disable on fail (default) or enable on fail.
Configuration Instructions
Define whether the panel will sound the exit/entry warning beeps during exit and entry delays or
not. An additional option is to mute the warning beeps only when the system is armed "HOME".
Options: ON (default), OFF when home (default in USA) and OFF, and OFF exit home.
Note: When exit beeps are OFF, the happy (success) melody will still sound toward the end of
an exit delay.
The volume level of the exit / entry beeps can be modified by pressing the
the keypad to increase the volume, or by pressing the
Define whether the panel will sound the exit/entry warning beeps during exit and entry delays or
not. An additional option is to mute the warning beeps only when the system is armed "HOME".
The control panel's display is: Def:P1
The pushbuttons
,
Pressing each button repeatedly will toggle between each option.
Options:
(enable beeps), H (OFF when home) h (OFF exit home) and
Notes:
When exit beeps are OFF, the happy (success) melody will still sound toward the end of an
exit delay.
The volume level of the exit / entry beeps can be modified by pressing the
the keypad to increase the volume, or by pressing the
Under trouble conditions, the panel sounder emits a series of 3 short reminder beeps once per
minute. Define whether to enable or disable this reminder beeping or just disable it at night.
The "night" hours are defined in the factory but are usually from 8 PM (20:00) until 7:00 AM.
Options: ON (default in USA); OFF at night (default) and OFF.
Note: Audible trouble beeps to be enabled for UL Listed product.
Define whether or not the user will receive "Memory" LCD indication that an alarm has been
activated. By pressing the
memory.
Options: ON (default) and OFF.
Note: For UL installations, set to "ON".
You can activate or deactivate the "Low Battery Acknowledge" requirement from the user whose
keyfob's battery is low. For further information, see PowerMaster User's Guide Chapter 5.
Options: OFF (default) – acknowledge not needed; ON – acknowledge required.
Note: For UL installations, Low Battery Acknowledge must be set to "ON".
Define whether the panel's back lighting will remain on at all times or will turn on only when a
key is pressed and turn off within 10 seconds if no further keystrokes are sensed.
Options: always ON and OFF after 10 sec (default).
.
P2
P3
, and
provide selection of the corresponding partitions.
button in standby mode, you can view details of the alarm
D-304762 PowerMaster-10/30 G2 Installer's Guide
button on
button to decrease the volume.
(disable beeps).
button on
button to decrease the volume.