Option
63:ZONE RESTORE
64:SYST.INACTIVE
1
65:TWO WAY VOICE
→ → → → Send 2wv code
Voice <- -> C.S.
→ → → →
Ringback time
→ → → →
Ambient level
→ → → →
(Return)
Master Installer only for
Send 2wv code /
Voice <--> C.S. /
Ringback time
Send 2wv code
Voice <- -> C.S
Ringback time
Ambient level
66:24H ZONE RPRT
Applicable in UK only
Event Reporting Chart
To simplify the configuration of reporting system events to Monitoring Stations, the event messages are divided into 5
Event Groups as described in the following table below: Due to lack of space in the display, the following abbreviations
are used alrm, alrt, o/c" and all (i.e. all events).
Event Group
Abbr. Events Messages Reported
Alarms
alrm
Open/close
o/c
Alerts
alrt
Maintenance
-
Trouble
-
Note: "Alarms" group has the highest priority and "Alerts" group has the lowest priority.
1
Refers to PowerMaster-30 G2 with voice option only
D-304762 PowerMaster-10/30 G2 Installer's Guide
Configuration Instructions
Close"). The report enabled option sends a "recent closing" report to the Monitoring Station if
an alarm occurs within 2 minutes from the end of the exit delay.
Options: report disabled (default) and report enabled
Notes:
1. CP-01 was tested and certified by ETL/Intertek.
2. CP-01 features not to be enabled in UL Listed product.
Some Monitoring Stations require that following an alarm event from a specific zone, the
system will also report when the alarming zone has restored to normal.
Options: report enabled (default) and report disabled
The PowerMaster can report a "System Inactive" event message (CID event 654) to the
Monitoring Station if the system is not used (i.e. armed) during a predefined time period.
Options: report disabled (default); after 7/14/30/90 days.
You can configure the two way voice channel settings of the control panel
Send 2 WV Code: Define whether the system will send two-way voice code to the Monitoring
Station (to turn the Monitoring Station from data communication to voice communication
state) by using pre-selected SIA or Contact-ID communication format only.
Voice <--> C.S.: Select the timeout for 2-way voice communication with Monitoring Stations, or
enable the Monitoring Station to ring back for 2-way voice function. This option is applicable only
after reporting an event to the Monitoring Station for listening and speaking.
Ringback Time: Define the period during which the Monitoring Station can establish 2-way
voice communication with the control panel
A. Alarm type message was received by Monitoring Station.
B. Ring Back function was selected (see "Voice <--> C.S." sub menu above).
Ambient Level: Select the ambient noise level of the installation. If it is a relatively noisy
environment, set it to High (default setting). If it is a very quiet environment, set to Low.
Note: Two-way voice not to be enabled on UL Listed product.
Options: don't send (default); and send.
Options: disable (default); timeout 10/45/60/90 s; timeout 2 m; and ringback.
Note: If "ring back" is selected, you should select "disable report" for private telephone (see
Option "01:REPORT EVENTS"), otherwise the Monitoring Station will establish communication
1
with the control panel
(after an event occurrence) in the normal manner (and not after one ring).
Options: 1 (default)/3/5/10 minute(s).
Options: low (default); and high.
Define whether 24 hour (silent and audible) zones will function as normal 24 hour zones or as
panic zones.
Options: audibl as panic; silent as panic; both as panic; and both burglary (default).
Fire, CO, Burglary, Panic, Tamper
Arming AWAY, Arming HOME, Disarming
No-activity, Emergency, Latchkey
Low-battery, AC failure
All other Trouble events not indicated above, e.g. Missing, Jamming, Communication Fail etc.
1
(after 1 ring), if:
5. PROGRAMMING
1
, as follows:
51