IMO Jaguar CUB Instruction Manual page 59

Compact inverter
Table of Contents

Advertisement

Table 3.6 Drive Monitoring Display Items
LED
monitor
Contents
Unit
shows:
3_00
Output
Hz
frequency
3_01
Output
Hz
frequency
3_02
Output
A
current
3_03
Output
V
voltage
3_05
Set
Hz
frequency
3_06
Running
N/A
direction
3_07
Running
N/A
status
3_09
Load shaft
rpm
speed
(m/min)
(line speed)
3_10
PID process
N/A
commands
3_11
PID feedback
N/A
amount
Description
Output frequency before slip compensation
Output frequency after slip compensation
Output current
Output voltage
Set frequency
Displays the running direction currently being outputted.
F: forward; R: reverse, – – – –: stop
Displays the running status in hex. format. Refer to " Displaying
running status " on the next page.
The unit for load shaft speed is rpm and that for line speed is
m/min.
Display value = (Output frequency Hz before slip compensation)
(Function code E50)
appears for 10000 (rpm or m/min) or more. When
appears, decrease function code E52 data so that the LED
monitor displays 9999 or below, referring to the above equation.
These commands are displayed through the use of function
code E40 and E41 data (PID display coefficients A and B).
Display value = (PID process command)
If PID control is disabled, "– – – –" appears.
This value is displayed through the use of function code E40
data and function code E41 data (PID display coefficients A and
B).
Display value = (PID feedback amount) (PID display coefficient
A - B) + B
If PID control is disabled, "– – – –" appears.