Chapter 4 Running The Motor; Running The Motor For A Test; Inspection And Preparation Prior To The Operation; Turning On Power And Checking - IMO Jaguar CUB Instruction Manual

Compact inverter
Table of Contents

Advertisement

Chapter 4
RUNNING THE MOTOR

4.1 Running the motor for a test

4.1.1 Inspection and Preparation prior to the Operation

Check the following prior to starting the operation.
(1) Check if connection is correct.
Especially check if the power wires are connected to inverter output terminals U, V and W and
that the grounding wire is connected to the ground electrode correctly.
• Do not connect power supply wires to the inverter output terminals U, V, and W. Otherwise,
the inverter may be broken if you turn the power on.
• Be sure to connect the grounding wires of the inverter and the motor to the ground
electrodes.
Otherwise, electric shock may occur.
(2) Check for short circuits between terminals
and exposed live parts and ground faults.
(3) Check for loose terminals, connectors and
screws.
(4) Check if the motor is separated from
mechanical equipment.
(5) Turn the switches off so that the inverter
does not start or operate erroneously at
power-on.
(6) Check if safety measures are taken against
runaway of the system, e.g., a defense to
protect
people
from
approaching your power system.

4.1.2 Turning on Power and Checking

• Be sure to install the terminal cover before turning the power on.
Do not remove the cover during power application.
• Do not operate switches with wet hands.
Otherwise electric shock could occur.
Turn the power on and check the following points. This
is a case when no function code data is changed from
the factory setting.
(1) Check if the LED monitor displays "0.00" (means
that the set frequency is 0 Hz) that is blinking.
(See Figure 4.2)
If the LED monitor displays numbers except
"0.00," then rotate the potentiometer to set "0.00"
as the set frequency.
(2) Check if a built-in cooling fan rotates (for models
with 1.5 kW or more).
Figure 4.1 Connection of Main Circuit Terminals
(Three-phase power supply)
unexpectedly
Figure 4.2 Display of the LED Monitor
after Power-on
4-1