IMO Jaguar CUB Instruction Manual page 112

Compact inverter
Table of Contents

Advertisement

If P99 (Motor characteristics) is set to 0 (Standard motors), 3 (Conventional motors), or 4 (Other
motors):
Setting
range
Power
Applicable
(kW)
motor rating
supply
(kW)
voltage
Function code
P02
0.01 to 0.06
0.06
0.07 to 0.10
0.1
0.11 to 0.20
0.2
0.21 to 0.40
0.4
0.41 to 0.75
0.75
0.76 to 1.50
1.5
1.51 to 2.20
2.2
2.21 to 3.70
3.7
3.71 to 5.50
5.5
5.51 to 10.00
7.5
0.01 to 0.06
0.06
0.07 to 0.10
0.1
0.11 to 0.20
0.2
0.21 to 0.40
0.4
0.41 to 0.75
0.75
0.76 to 1.50
1.5
1.51 to 2.20
2.2
2.21 to 3.70
3.7
3.71 to 5.50
5.5
5.51 to 10.00
7.5
NOTE: The above values in the "Rated current" column are applicable to four-pole standard motors rated
for 200 V and 400 V at 50 Hz. If you use non-standard motors, change the P02 data to the rated current
printed on the motor's nameplate.
Rated current (A)
If P99 (Motor selection) is set to:
0
3
0.44
0.44
0.68
0.68
1.30
1.30
2.30
2.30
3.60
3.60
6.10
6.10
9.20
9.20
15.00
15.00
22.00
22.00
29.00
29.00
0.22
0.22
0.34
0.34
0.65
0.65
1.15
1.15
1.80
1.80
3.05
3.05
4.60
4.60
7.50
7.50
11.00
11.00
14.50
14.50
5-40
4
0.44
0.68
1.30
2.30
3.60
6.10
9.20
15.00
22.00
29.00
0.22
0.34
0.65
1.15
1.80
3.05
4.60
7.50
11.00
14.50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents