Lantronix SLC 8000 User Manual page 327

Advanced console manager
Hide thumbs Also See for SLC 8000:
Table of Contents

Advertisement

14: Command Reference
show vpn viewlog [numlines <Number of Lines] [email <Email Address>]
Display RSA public key of the SLC:
show vpn rsakey
set temperature
Syntax
set temperature
Description
Sets the acceptable range for the internal temperature sensor (an SNMP trap is sent if the
temperature is outside of this range). Temperatures can be entered in either Celsius or
Fahrenheit; to indicate a temperature is Fahrenheit, append the degrees with an 'F', i.e., "75F".
Parameter
set temperature <one or more parameters>
Parameters: low <Low Temperature in C. or F.>
high <High Temperature in C. or F.>
calibrate <Temperature Calibration in C. or F.|cancel>
Note:
The calibration offset will be applied one hour after setting the value.
Description
Displays the acceptable range and the current reading from the internal temperature sensor.
show temperature
Syntax
show temperature
Description
Shows the temperature.
SLC™ 8000 Advanced Console Manager User Guide
327

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLC 8000 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF