Serial Communication; Introduction - WEG CFW08 Vector inverter User Manual

Vector frecuency inverter
Table of Contents

Advertisement

CONTROL POWER
8.19 SERIAL
COMMUNICATION

8.19.1 Introduction

CONTACTOR
POWER
SUPPLY
OVERLOAD
RELAY
SUPPLY
THERMOSTAT
(only for models 7.3-10-16A/200-240V e 2.7-4.3-6.5-10-13-16/380-480V)
The basic objective of the serial communication is the physical connection
of the inverters in an equipment network configured as follows:
The inverters have a control software for data transmission/reception through
serial interface, thus facilitating the reception of data that have been sent
by the master and the transmission of the data requested by the master.
This software supports WEG protocol and nine different Modbus-RTU
modes, that can be selected via parameter P312. The subjects broached
in this Section refers to WEG protocol. For more details about the Modbus-
RTU, see item 8.19.
The transfer rate is 9600 bits/s, following an exchange protocol of question/
answer typeby using ASCII characters.
The master is able to realize the following operations related to each
inverter:
CFW-08 OPTIONS AND ACCESSORIES
R
S
T
BR
BRAKING
RESISTOR
Figure 8.23 - Braking resistor connection
Master
Slave 1
Slave 2
(Inverter)
(Inverter)
U
V
MOTOR
W
+UD
PC, PLC, etc.
Slave n
(Inverter)
n ≤ 30 for WEG Protocol
n ≤ 247 for Modbus-RTU
133