CFW-08 - QUICK PARAMETER REFERENCE
Parameter
Function
Analog Output
P251
Analog Output
AO Function
P252
Analog Output AO Gain
Digital Inputs
P263
(1)
Digital Input DI1 Function
P264
(1)
Digital Input DI2 Function
(1) (2)
P265
Digital Input DI3 Function
(1)
P266
Digital Input DI4 Function
(1)
This parameter can be changed only with the inverter disabled (motor stopped).
(2)
Value may change as a function of P203.
10
Adjustable Range
0 = Output Frequency (Fs)
1 = Input Reference (Fe)
2 = Output Current (Is)
3, 5, 8 = Not used
4 = Motor Torque
6 = Process Variable
(PID)
7 = Active Current
9 = PID Setpoint
0.00 ... 9.99
0 = No Function or
General Enable
1 ... 7 and 10 ... 12 =
General Enable
8 = Forward Run
9 = Start/Stop
13 = FWD Run Using
Ramp #2
14 = Start (3-wire)
0 = Forward/Reverse
1 = Local/Remote
2 ... 6 and 9 ... 12 = Not used
7 = Multispeed (MS2)
8 = Reverse
13 = REV Run - Ramp #2
14 = Stop (3-wire)
0 = Forward/Reverse
1 = Local/Remote
2 = General Enable
3 = JOG
4 = No External Fault
5 = Increase E.P.
6 = Ramp #2
7 = Multispeed (MS1)
8 = No Function or
Start/Stop
9 = Start/Stop
10 = Reset
11, 12 = Not used
13 = Flying Start Disable
14 = Multispeed (MS1)
Using Ramp #2
15 = Manual/Automatic PID)
16 = Increase E.P. with
Ramp #2
0 = Forward/Reverse
1 = Local/Remote
2 = General Enable
Factory
User
Setting
Setting
Only available
0
in CFW-08
Plus version.
1.00
0
0
10
8
Note
Page
88
88
89
89
89
89