WEG CFW08 Vector inverter User Manual page 87

Vector frecuency inverter
Table of Contents

Advertisement

DETAILED PARAMETER DESCRIPTION
Parameter
(1)
P229
Local Command
Selection
P230
(1)
Remote Command
Selection
P231
(1)
Forward/Reverse -
Local/Remote Modes
P234
Analog Input AI1
Gain
(1)
This parameter can be changed only with the inverter disabled (motor stopped).
86
Range
[Factory Setting]
Unit
Description / Notes
Define the control sources for the inverter enabling disabling
0...2
[ 0 - Keys ]
FWD/REV and JOG.
-
0...2
[ 1 - Terminals ]
-
The direction of rotation is the only operation control that depends
on other parameter for operation - P231.
For more details, refer to Items 6.2.4, 6.2.5 and 6.2.6.
0...2
Defines the direction of rotation.
[ 2 - Commands]
-
0.00...9.99
The analog inputs AI1 and AI2 define the inverter frequency reference
[ 1.00 ]
as shown in the curve below.
0.01
Figure 6.17 - Determination of the frequency reference from the analog
Note that there is always a dead zone at the starting of the curve
where the frequency reference remains at the value of the
minimum frequency (P133), even when the input signal is changed.
This dead zone is only suppressed when P133=0.00.
P229/P230
0
HMI-CFW08-P or HMI-CFW08-RP Keypad
1
Terminals (XC1)
HMI-CFW08-RS keypad
2
or serial interface
P231
Direction of rotation
0
Always forward
1
Always reverse
Commands as defined in
2
P229 and P230
Frequency Reference
P134
P133
0
0 ..................... 100%
0 ........................ 10V (P235/P239=0)
0 ..................... 20mA (P235/P239=0)
4mA .................. 20mA (P235/P239=1)
inputs AI1 and AI2
Control source
AI1/AI2