Between the MCNT and OPE, serial data is transferred via the SIO incorporated in the CPU1.
<Communication method>
1)
Communication method : Start-stop synchronization
2)
Transfer rate
3)
Data length
<Data configuration>
1)
Status bit
2)
Data
3)
Even parity
4)
Stop bits
Error = ±5%
D0
START
BIT
Figure A.24 (3/4) Communication signal (TXDOPE/RXDOPE) between MCNT and OPE
CPU1
SH7034
PC1V (+5 V)
to OPE
PC1G (0 V)
PC2V (+5 V)
PC2G (0 V)
41309401TH Rev.4
: 5832 bps
: 8 bits
: 1 bit
: 8 bits
: 1 bit (ignored by OPE)
: Bits 1 and 5
D1
D2
D3
R46
to OPE
PC1-N
PC2-N
Figure A.24 (4/4) Related Signals of PC1/PC2
D4
D5
D6
D7
CN3
1
2
3
4
5
6
Note: PC1 (presence of document on hopper)
PC2 (presence of document at scanning position)
EVEN
PARITY
STOP
BIT
PC1
PC2