List Of Get Commands - Pioneer PDP-V401 Technical Manual

Plasma display
Hide thumbs Also See for PDP-V401:
Table of Contents

Advertisement

Outer control by RS232C

5.3.4 List of GET commands

What are GET commands?
• Commands to output adjustment data from the PC connected to the plasma display to another personal computer
• Adjustment data is output for each input function, each input mode, and each mode.
• Adjustment data is output in ASCII.
Note: Data in < > indicates a command name.
1) <GPS> (GET POSITION DATA) — Phase-adjustment data is output in the following format:
(1) STX (02H)
(2) Adjustment data for <CFR>/CLOCK FREQ (3BYTE).
(3) Adjustment data for <CPH>/CLOCK PHASE (3BYTE).
(4) Adjustment data for <HPS>/HOR.POSITION (3BYTE).
(5) Adjustment data for <VPS>/VER.POSITIOIN (3BYTE).
(6) ETX (03H)
Note:Not valid when VIDEO and Y/C are input.
2) <GWB> (GET W/B DATA) — Data for picture quality and white-balance are output in the following format:
(1) STX (02H)
(2) Adjustment data for <CNT>/CONTRAST (3BYTE).
(3) Adjustment data for <BRT>/BRIGHTNESS (3BYTE).
(4) Adjustment data for <COL>/COLOR (3BYTE). Note 1)
(5) Adjustment data for <TNT>/TINT (3BYTE). Note 1, 2)
(6) Adjustment data for <SHP>/SHARPNESS (3BYTE). Note 1)
(7) Adjustment data for <RHI>/RED HIGH-LIGHT (3BYTE).
(8) Adjustment data for <GHI>/GREEN HIGH-LIGHT (3BYTE).
(9) Adjustment data for <BHI>/BLUE HIGH-LIGHT (3BYTE).
(10) Adjustment data for <RLW>/RED LOW-LIGHT (3BYTE).
(11) Adjustment data for <GLW>/GREEN LOW-LIGHT (3BYTE).
(12) Adjustment data for <BLW>/BLUE LOW-LIGHT (3BYTE).
(13) ETX (03H)
Note: 1) When the input function is INPUT = RGB 1, 2, dummy data is output.
2) The dummy data is output when PAL signals are input for PDP-V401E.
3) <GST> (GET STATUS) — The status of each setting is output in the following format:
(1) STX (02X)
(2) PC software version
Example: V1.00: Indicates version 1.00.
(3) Input function status
Example: IN1: Indicates VIDEO input.
(4) COLOR MODE Status
Example: CM1: COLOR MODE = 1.
(5) OSD indication, Enable/Disable setting state
Example: DIY: Indicate OSD indication and Enable.
(6) Remote control Enable/Disable status, and operation panel
Example: KLY: Indicates Operation Disabled.
(7) ETX (03H)
130
<Ver. 2.1>
(5 BYTE): Output by command name.
(3 BYTE): Output by command name.
(3 BYTE): Output by command name.
(3 BYTE): Output by command name.
(3 BYTE): Output by command name.