Pioneer PDP-V401 Technical Manual page 81

Plasma display
Hide thumbs Also See for PDP-V401:
Table of Contents

Advertisement

7 Suspending connected plasma displays using wires
More than one display can be connected, as shown in the figure. (Maximum: 3 displays)
When wires are fixed to the ceiling, use two wires fixed at two independent points.
Hole (9-mm dia.)
Hole (9-mm dia.)
• To prevent plasma displays from tilting, fix them with
wires that pass through the bottom bolts.
• When more than two displays are to be hung, use
as many wires as needed to withstand the total
weight (30.8 kg <31.6 kg> for a plasma display and
3.3 kg for a PDP bracket).
• For the temperature or other conditions, see the
description in "Special installation, Ceiling
suspension (using wires)."
< > shows the PDP-V401E.
In this case, do not use special eye bolts.
All wires must pass through the φ 9-mm hole.
Caution
Caution
Mounting standard metal fixtures (PDK-4005)
Hole (9-mm dia.)
Hole (9-mm dia.)
Eye bolt
For the following reasons, we do not recommend substitution of JIS-
standard eye bolts for special eye bolts:
1. Since the eye-bolt screw is too short to prevent loosening, nuts
Finger spring
cannot be used.
2. The finger spring may be used to help prevent loosening, but may
not provide adequate torque for this specific purpose.
Hole (9-mm dia.)
Wire
81
<Ver. 2.1>

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents