Special installations (Wall embedding)

3.4.3 Wall embedding

This display is designed to accommodate embedding in a wall. Note that the allowable range of outside-air temperature
depends on the installation conditions. Please observe the following requirements:
1 If the unit must be embedded in the wall, you must not block the side slots of the unit.
Avoid blocking the ventilating holes in the rear as much as possible.
2 Use a metal mounting fixture that does not block the side slits or the back ventilation holes, and attach at a
minimum of four points. To avoid breaking the PDP panel, limit any twisting or bending stress applied to the
display to 1 mm or less.
3 Do not use cable clamps for this installation method. Cable clamps can interfere with proper ventilation and
result in device failure.
4 Installation conditions and ambient operating temperatures:
(1) If the back of the display will be unobstructed:
B
A
100 mm
B
24
<Ver. 2.1>
Side slits
C
B
A
Intake
A ≥ 100 mm, B ≤ 150 mm
A ≥ 100 mm, B ≥ 150 mm
A ≤ 100 mm, B ≤ 80 mm
100 mm
A ≤ 100 mm, B ≥ 80 mm
Take C to be 30 mm or more.
A
Never block the side slots. Avoid
blocking the ventilating holes of the
unit as much as possible.
Caution
X
Y
Exhaust
X, Y space upper temperature limits
40 °C
40 °C (Animation), 35 °C (Still)
40 °C
35 °C
MAX 20 mm
C
B
A