Table of Contents

Advertisement

6.2.2 Starting

Check that the generating set circuit breaker has triggered.
Danger
Connect the generating set battery
Turn the key switch to the ON position (without forcing it to the ON position), the ON lamp will light up (if the lamp does not light
up, check and replace the fuse if necessary)
Test the Alarm and Fault LEDs (menu 15 – TEST LAMPS)
1 ACTIONS
1/5
11 MANUAL <> AUTO
12 CONTROL LOAD
13 TEST GENERATING SET
14 PROGRAMS
15 TEST LAMPS
OK
Esc
Press "Esc" several times to return to the following home menu
OPERATION
MANUAL
Press START
to start
24/08/2005
Check the battery voltage
Press START:
AIR PREHEATING
10 seconds
24/08/2005
If the engine is equipped with an air
preheating system, there is a delay
(adjustable) before the engine starts
(preheating activation period).
If the motor is not fitted with an air
preheating
system
or
preheating delay has elapsed, the
engine starts up (start of a cycle
comprising 3 attempts to start up the
engine).
13:12
24/08/2005
13:12
Warning: the number of successive and
automatic starting attempts is limited to 3.
The following pictogram will flash
once
the
START-UP
IN PROGRESS
13:12
47/285
AVAILABLE POWER
100.0%
24/08/2005
The following pictogram is displayed
The following information is displayed
Speed of rotation
Coolant temperature
Oil pressure
Oil Temperature
13:12