5. Preparation before operating the set

The inspections referred to in this section enable the electrical generator set to operate.
Specific skills are required to carry out these operations.
They must only be entrusted to personnel with the necessary skills.
Failure to follow these instructions in any way could result in malfunction or very serious accidents.
Danger

5.1. Installation checks

check that the general recommendations given in the installation section (ventilation, exhaust, fluids, etc.) are
observed.
carry out the level checks (oil, water, diesel fuel, battery).
check the generating set earth connection is earthed.
check that the electrical connections are in order.

5.2. Checks after starting the generating set

carry out the mechanical checks (oil pressure, water temperature, absence of noise etc.)
carry out the electrical checks (voltage and frequency)
carry out the safety checks (emergency stop, oil pressure, water temperature etc.)

6. Using the generating set

6.1. Pre-Start Inspection

Engine and engine compartment, general check
Visually check the engine and engine compartment before starting the engine and after stopping the engine.
Check:
 there are no oil, fuel or coolant leaks,
 the screws are tightened,
 the condition of the belts (wear, tension).
Fuel, oil and grease deposits on the engine or in the engine compartment are always a fire hazard and must be
removed as soon as they are noticed.
Warning
If there are any oil, fuel or coolant leaks, locate the origin of the fault and repair it immediately before starting the
engine.
Important
Never use a high pressure cleaner for cleaning the engine and equipment.
Important
33/298