8.2.

Battery setting into service

Batteries filled with acid have a density of 1.28 g/ml and are charged.
In the case of dry batteries, fill each battery cell with acid up to the maximum level mark or to 15 mm above the plates. Let the
battery rest for 20 minutes.
Before fitting the battery, stop the engine and any power consumer, clean the terminals and give them a light coating of grease.
When connecting, connect the positive terminal (+) first, and then the negative terminal (-).
8.3.

Check

Acid density
1.27
1.25
1.20
1.19
1.13
Charge status
100%
80%
60%
40%
20%
Voltage when idle
Above 12.60 V
12.54 V
12.36 V
12.18 V
Under 11.88 V
120/285
From 50 % recharge
Risk of sulphation
Unusable