Preparation Before Starting; Using The Generator Set - SDMO HX 3000-C Generating Set User And Maintenance Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13

3. Preparation before starting

3.1. Checking the oil level
Always check the engine oil level before starting.
Checking and topping up should be carried out with the generating set on a horizontal surface.
Remove the grey-coloured dipstick/plug (no. 1, diag. B) on the exhaust side by unscrewing it, and wipe the dipstick.
Insert the dipstick into the filler neck (no. 2, diag. B) without screwing it in.
Note: A second, black, plug (no. 3, diag. A), without a dipstick, is available if necessary on the other side of the engine.
Check the level and top up if necessary. If it is necessary:
Using a funnel, fill the engine oil sump right up to the top of the filler opening.
Screw the plug fully back onto the filler tube.
Check that there are no leaks.
Wipe off excess oil with a clean cloth.
3.2. Checking the fuel level
Stop the engine before filling up with fuel and fill up in a well-ventilated area.
Do not smoke, or bring naked flames or sparks near to the area where you are filling up with fuel or where the
fuel is stored.
Danger
Only use clean fuel without any water.
Do not overfill the tank (there should not be any fuel in the filler neck).
When you have filled up, ensure that the tank cap is closed correctly.
Take care not to spill any fuel when filling the tank.
Before starting up the generating set, and if any fuel has been spilt, make sure that it has dried and that the
vapours have cleared away.
Check the fuel level and top up if necessary:
Unscrew the fuel tank cap (no. 2, fig A).
Fill the tank (no. 1, fig A) using a funnel, taking care not to spill petrol.
Screw the cap back on to the fuel tank.
3.3. Earthing the generating set
To earth the generating set, use a 10 mm2 copper wire attached to the generating set earth connection and to an earthing rod of
galvanised steel set in the ground to a depth of 1 metre. This also dissipates the static electricity that builds up in the electrical
machines.
3.4. Positioning the generating set for operation
Place the generating set on a flat, horizontal surface which is firm enough to prevent the set sinking down (under no circumstances
should the set tilt any direction by more than 10°).
Choose a site that is clean, well-ventilated and sheltered from bad weather, and store the additional supplies of oil and fuel within
close proximity, although respecting a certain distance for safety.

4. Using the generator set

4.1. Starting procedure
Open the fuel tap by turning lever (no.14, diag. A) to the right.
Move the choke knob (no. 15, diag. A) to the closed position as shown on the illustration.
Note: Do not use the choke when the engine is warm or when the atmospheric temperature is high.
Move the engine switch (no.10, diag. A) to "ON" or "I".
Hold starting handle (no. 13, diag A) correctly and pull it slowly until some resistance is felt, then let it return gradually.
Take the starting handle again correctly, then pull the cord sharply and rapidly (pull it right out, using both hands if necessary).
Allow the handle to return slowly by hand. If the engine has not started, repeat the procedure until the engine starts while
gradually opening the choke.
When the engine has started, gradually open the choke.
4.2. Operation
When the engine begins to heat up, gradually bring the knob of the choke to open position.
When the running speed of the generating set has stabilised:
Check that circuit breaker (no. 22, fig A) is engaged.
Connect the plug(s) to the generating set socket(s).

Advertisement

Table of Contents
loading

Table of Contents