Summary of Contents for SDMO SH 6000-2 UK

  • Page 1 SH 6000-2 UK – SH 6000E-2 UK GENERATING SET USER MAINTENANCE MANUAL 33522127601_0_1 AЯ46...
  • Page 5: Table Of Contents

    Contents 1. Preface 7. Maintenance procedures 2. General description 8. Storing the generating set 3. Preparation before starting 9. Fault finding 4. Using the generator set 10. Specifications 5. Safety features (if fitted, see specifications table) 11. Cable sizes 6. Maintenance schedule 12.
  • Page 6 1.3.2 General advice One of the fundamental safety considerations is observation of the interval between maintenance procedures (see maintenance schedule). Furthermore, never attempt to carry out repairs or maintenance procedures without the necessary experience and/or tools. When you take delivery of your generating set, check that it is complete and not damaged in any way. A generating set should be handled gently, avoiding sudden movements, and the place where it is to be stored or used should be carefully prepared beforehand.
  • Page 7 1.3.8 Safety guidelines for handling batteries Never place the battery close to a flame or fire Use only insulated tools Never use sulphuric acid or acid water to top up the electrolyte level. Danger 1.3.9 Protecting the environment Never drain or discard used oil onto the ground, but put it into a designated container. As far as possible, try to avoid sound reverberating through walls and buildings, as the noise will be amplified.
  • Page 8 Check that the earth wire is properly connected to the bolt (No. 1, fig. B) Turn the knob to open the main fuel tap (No.3, fig. A) located underneath the tank. Generating set model SH 6000-2 UK Generating set model SH 6000 E-2 UK Turn the On/Off switch (No.
  • Page 9: Maintenance Procedures

    6. Maintenance schedule 6.1. Reminder of use The maintenance interval frequency and the operations to be carried out are outlined in the maintenance programme. However, it should be added that it is the environment in which the generating set is operating which determines this programme. Accordingly, if the set is used in extreme conditions, shorter intervals between maintenance procedures should be adopted.
  • Page 10 7.4. Cleaning the spark arrester (diagram K) Never use petrol or flammable solvents for cleaning the air filter element as this could result in a fire or explosion. Danger Loosen the two nuts (1) by 12 mm and remove the cylinder silencer (2). Loosen by 5 mm the five bolts (3) and (4) holding the silencer guard (5) and then remove silencer guard.
  • Page 11: Storing The Generating Set

    8. Storing the generating set Generating sets which are to remain unused for a long period of time must undergo certain procedures, in order to keep them in good condition. Check that the storage area is not dusty or humid. Clean the exterior of the generating set and apply rustproofing product. Close the fuel tap (O position), remove the sediment bowl and drain it.
  • Page 12: Cable Sizes

    16.0 mm 6.0 mm 16.0 mm 16.0 mm 12. EC Declaration of conformity Name and address of manufacturer SDMO, 12 bis rue de la Villeneuve, CS 92848, 29228 BREST CEDEX 2 Description of the equipment Product Generating set Make SDMO Type SH 6000-2 UK–...

This manual is also suitable for:

Sh 6000e-2 uk