Fuel
Fuel type
Standard fuel tank
High autonomy fuel tank
Lubrication
Oil capacity with filter
Min. Oil pressure
Nominal oil pressure
Oil consumption (100 % load)
Oil sump capacity
Type of lubricant
Cooling
Engine capacity with radiator
Max coolant temperature
Fan power
Ventilator air flow
Refrigerant type
Thermostat
Alternator data
● Compliant with NEMA MG21 standards, UTE NF C51.111,
VDE 0530, BS 4999, IEC 34.1, CSA
Type
Number of phases
Power factor (cos Phi)
Number of poles
Excitation type
Voltage regulator
Short-circuit current
Number of bearings
Coupling
Control unit(s)
TELYS
KERYS
Diesel
470 L
1368 L
35 L
0.7 bar
6 bar
0,06 L/h
28 L
Genlub
41 L
103 °C
17.8 kW
3
7.2 m
/s
Gencool
82-92°C
● The alternator is protected against short circuits
● Vacuum impregnation, epoxy winding, IP23 protection rating
LEROY SOMER LSA462VL12
3
0.8
4
AREP
R450
3 IN
1
Direct
Standard specifications:
Voltmeter, Ammeter, Frequency meter
Alarms and faults:
Oil pressure, Water temperature, Start failure, Overspeed,
Alternator min/max, Battery voltage min/max, Emergency stop
Engine parameters:
Timer, Oil pressure, Water temperature, Fuel level, Engine
speed, Battery voltage
Coupling: pre-programmed coupling mode selector.
Electrical measurements:
Voltmeter, Ammeter, Frequency meter
Alarms and faults:
Oil pressure, Water temperature, Start failure, Overspeed,
Alternator min/max, Battery voltage min/max, Emergency stop
Engine parameters:
Timer, Oil pressure, Water temperature, Fuel level, Engine
speed, Battery voltage
Additional specifications :Coupling Website, Troubleshooting,
Assistance and maintenance, plotting and logging, load
impact, 8 configurations available, Compliance with
international standards...
18/285