SDMO SH 3000 UK Maintenance Manual

SDMO SH 3000 UK Maintenance Manual

Generating set

Advertisement

SH 3000 UK
GENERATING SET USER
AND
MAINTENANCE MANUAL
33522129301_0_1

Advertisement

Table of Contents
loading

Summary of Contents for SDMO SH 3000 UK

  • Page 1 SH 3000 UK GENERATING SET USER MAINTENANCE MANUAL 33522129301_0_1...
  • Page 2 UK MODEL...
  • Page 5: Table Of Contents

    Contents 1. Preface 7. Maintenance procedures 2. General description 8. Storing the generating set 3. Preparation before starting 9. Fault finding 4. Using the generator set 10. Specifications 5. Safety features (if fitted, see specifications table) 11. Cable sizes 6. Maintenance schedule 12.
  • Page 6 This symbol indicates a dangerous situation if the warning is not heeded. Not following this instruction could result in non-serious injury or damage. Warning 1.3.2 General advice One of the fundamental safety considerations is observation of the interval between maintenance procedures (see maintenance schedule).
  • Page 7: General Description

    1.3.6 Filling with fuel The fuel is highly flammable and its vapours are combustible. Smoking, using a naked flame or producing sparks are forbidden while the fuel tank is being filled. Filling should be carried out with the motor turned off. All traces of fuel should be wiped off with a clean cloth. Danger Always place the generating set on a flat, level and horizontal surface to avoid fuel spillage from the tank onto the motor.
  • Page 8: Preparation Before Starting

    3. Preparation before starting 3.1. Checking the oil level Always check the engine oil level before starting. Tasks such as topping up the oil should be carried out with the generating set on a horizontal surface. Remove cap (no. 1, Diag.B) by unscrewing it. Check the level and top it up if necessary.
  • Page 9: Safety Features (If Fitted, See Specifications Table)

    4.3. Switching off When the generating set is turned off, the engine continues to give off heat. Appropriate ventilation should be provided after the generating set is turned off. To stop the generating set urgently, place the engine switch on "OFF" or "О". Warning Take the plugs out of the sockets and allow the engine to run without any charge for 1 to 2 minutes.
  • Page 10 7.2. Renewing the motor oil Change the oil when the engine is still warm, to ensure that drainage is rapid and complete. Remove the filling plug-gauge (no. 1, diag. G) and the drain plug (no. 2, diag. G) and drain the oil into a suitable container. On completion, screw up again and tighten the drain plug (no.
  • Page 11 Have it checked, repaired or replaced Circuit breaker trips Probable causes Remedial action Faulty equipment or lead Have it checked, repaired or replaced 10. Specifications Model SH 3000 UK Engine type HONDA GX 200 Output (Watts) 3000 Direct current Alternating current 115V/26A...
  • Page 12: Ec Declaration Of Conformity

    16.0 mm 6.0 mm 16.0 mm 16.0 mm 12. EC Declaration of conformity Name and address of manufacturer SDMO, 12 bis rue de la Villeneuve, CS 92848, 29228 BREST CEDEX 2 Description of the equipment Product Generating set Make SDMO...