SPN
CID
SID
PID
282
282
285
285
286
286
323
323
324
324
412
443
443
523
608
250
608
608
611
620
262
232
PPID
FMI
3
4
3
4
3
4
5
3
4
5
3
4
5
0
3
4
15
16
3
4
9
132
98
3
4
3
4
Description
Overspeed output status
Overspeed output open/short to B+
Overspeed output short to ground
Coolant temperature output status
Coolant temperature lamp open/short to
B+
Coolant
temperature
lamp
ground
Oil pressure output status
Oil pressure output open/short to B+
Oil pressure output short to ground
Oil pressure output open circuit
Shutdown output status
Shutdown output open/short to B+
Shutdown output short to ground
Shutdown output open circuit
Warning output status
Warning output open/short to B+
Warning output short to ground
Warning output open circuit
Temperature sensor in the EGR valve.
Temperature in the EGR extremely high
Input voltage of the temperature sensor
high
Input voltage of the temperature sensor
low
Temperature in the EGR high
Temperature in the EGR moderately high
ENGINE RUN output status
Engine run output open/short to B+
Engine run output short to B-
Gear selection
Gear selection invalid
Data
link
faulty
J1587
redundancy / J1939 communication
bus
Redundancy of the accelerator
Redundancy
of
the
information
Injector wiring status
Injector wiring shorted to power source
Injector wiring shorted to ground
5 Volt sensor power supply
Sensor power supply open/short to B+
Sensor power supply short to ground
275/285
Comment
short
to
Short to V+
Short to V-
Not possible with Genset
application
Start/Stop
Stop/start
FMI
not
informed
VOLVO
by

Hide quick links: