SDMO R 340 U User And Maintenance Manual page 276

Table of Contents

Advertisement

SPN
CID
SID
PID
172
172
172
174
174
175
175
177
189
190
190
190
228
261
252
252
234
253
281
281
PPID
FMI
3
4
5
15
16
0
3
4
15
16
31
0
3
4
5
9
0
31
0
2
9
11
12
15
16
13
11
2
3
4
5
Description
Ambient air temperature sensor
Ambient air temperature sensor input
voltage high
Ambient air temperature sensor input
voltage low
Ambient air temperature sensor open
circuit
Fuel temperature sensor
Fuel temperature high most severe
Fuel temperature sensor input voltage
high
Fuel temperature sensor input voltage
low
Fuel temperature high
Fuel temperature moderately high
Fuel temperature sensor faulty
Oil temperature sensor
Oil temperature extremely high
Oil temperature sensor input voltage high
Oil temperature sensor input voltage low
Oil temperature sensor open circuit
Transmission oil temperature sensor
Transmission oil temperature invalid
Rated engine speed
Engine speed de rated
Engine speed de rated
Engine speed sensor
Overspeed extreme
Engine speed sensor data intermittent
Engine speed sensor abnormal update
Engine speed sensor signal lost
Engine speed sensor signal lost
Overspeed
Overspeed moderate
Speed sensor calibration
Engine timing abnormal calibration
Software
Incorrect engine software
Check system parameters
Incorrect parameters
Action alert output status
Action alert output open/short to B+
Action alert output short to ground
Action alert output open circuit
274/285
Comment
Inlet
air
temperature
sensor for PERKINS
Inlet air temperature sensor
input voltage high
Inlet air temperature sensor
input voltage low
High Inlet air temperature
alarm-warning
High Inlet air temperature
alarm-action alert
Not possible with Genset
application

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents