SPN
CID
SID
PID
653
3
3
653
654
4
4
654
655
5
5
655
PPID
FMI
0
1
2
3
4
5
6
7
11
0
1
2
3
4
5
6
7
11
0
1
2
3
4
5
6
7
11
Description
Cylinder #3 injector status
Injector outside the specifications
Injector outside the specifications
Short circuit high side to B+
Short circuit high side to low side or low
side to B+
Short circuit high or low side to ground
Cylinder #3 circuit open
Cylinder #3 circuit shorted
Cylinder #3 balancing error/mechanical
failure
Cylinder #3 unknown error/mechanical
failure
Cylinder #4 injector status
Injector outside the specifications
Injector outside the specifications
Short circuit high side to B+
Short circuit high side to low side or low
side to B+
Short circuit high or low side to ground
Cylinder #4 circuit open
Cylinder #4 circuit shorted
Cylinder #4 balancing error/mechanical
failure
Cylinder #4 unknown error/mechanical
failure
Cylinder #5 injector status
Injector outside the specifications
Injector outside the specifications
Short circuit high side to B+
Short circuit high side to low side or low
side to B+
Short circuit high or low side to ground
Cylinder #5 circuit open
Cylinder #5 circuit shorted
Cylinder #5 balancing error/mechanical
failure
Cylinder #5 unknown error/mechanical
failure
278/285
Comment
Recalibration of the injectors
required
Recalibration of the injectors
required
Recalibration of the injectors
required
Recalibration of the injectors
required
Recalibration of the injectors
required
Recalibration of the injectors
required