SDMO BOOSTER 1000 UK Generating Set User And Maintenance Manual

SDMO BOOSTER 1000 UK Generating Set User And Maintenance Manual

Generating set

Advertisement

BOOSTER 1000 UK
GENERATING SET USER
AND
MAINTENANCE MANUAL
33522120801_1_1

Advertisement

Table of Contents
loading

Summary of Contents for SDMO BOOSTER 1000 UK

  • Page 1 BOOSTER 1000 UK GENERATING SET USER MAINTENANCE MANUAL 33522120801_1_1...
  • Page 4 0.6 -0.7 mm...
  • Page 5: Table Of Contents

    Contents 1. Preface 7. Maintenance procedures 2. General description 8. Storing the generating set 3. Preparation before starting 9. Fault finding 4. Using the generator set 10. Specifications 5. Safety features (if fitted, see specifications 11. Cable sizes table) 12. Conditions of warranty 6.
  • Page 6 1.3. Instructions and safety regulations 1.3.1 Warnings You are likely to encounter several warning symbols in this manual. This symbol indicates a definite risk to the health and life of people. Not following this instruction may seriously affect the health of people or prove fatal. Danger This symbol draws attention to the potential risk to the health and life of people.
  • Page 7 1.3.4 Safety guidelines to prevent fire Keep all inflammable materials (e.g.: petrol, oil, fabric etc.) out of the way when the generating set is in operation. The motor should not be operated in areas containing explosive products. There is a risk of sparks forming where all electrical and mechanical components are not shielded.
  • Page 8: General Description

    1.3.12 Operating conditions The stated outputs of the generating sets are obtained in example conditions according to ISO 3046-1: +27° C, 100 m above sea-level, humidity level equal to 60 % or +20° C, 300 m above sea-level, humidity level equal to 60 %. Performance is reduced by approximately 4 % for every additional 10°C and/or approximately 1 % for every additional 100 m in altitude.
  • Page 9: Using The Generator Set

    4. Using the generator set Never run the generating set without an air filter. Do not run the generating set if the enclosure is not in place. Never take the enclosure off, if the generating set is running Danger 4.1. Fuel cap (diagrams K1 and K2) BEFORE STARTING THE ENGINE Turn the fuel cap lever (No.
  • Page 10: Safety Features (If Fitted, See Specifications Table)

    4.4. Switching off (diagram A) When the generating set is turned off, the motor continues to give off heat. Suitable ventilation should be provided after the generating set is turned off. To stop the generating set quickly, turn the On/Off switch to stop "О". Warning ❶...
  • Page 11: Maintenance Procedures

    7. Maintenance procedures Stop the motor before carrying out any maintenance procedure. To make allowances for any accidental spillage, switch off the motor ignition and disconnect the spark plug cap(s). Only use original parts or equivalent. The use of spare parts of a different quality can damage the generating set. Warning 7.1.
  • Page 12: Storing The Generating Set

    Circuit breaker Faulty equipment or lead Have it checked, repaired or replaced trips out 10. Specifications Model BOOSTER 1000 UK Motor type Honda GXH 50 50 Hz (Watt) output position Maximum 50 Hz output (Watt) position Alternating current (voltage and amperage) 230 V / 2.95 A...
  • Page 13: Cable Sizes

    11. Cable sizes Rated current Cable lengths 0 – 50 metres 51 – 100 metres 101 – 150 metres 1.5 mm 1.5 mm 2.5 mm 1.5 mm 2.5 mm 4.0 mm 2.5 mm 4.0 mm 6.0 mm 2.5 mm 6.0 mm 10.0 mm 2.5 mm 10.0 mm...
  • Page 14: Ec Declaration Of Conformity

    13. EC Declaration of conformity Name and address of manufacturer SDMO, 12 bis rue de la Villeneuve, CS 92848, 29228 BREST CEDEX 2 Description of the equipment Product Generating set Make SDMO Type BOOSTER 1000 UK G. Le Gall, the manufacturer's authorised representative, confirms that the product conforms to the following EC Directives: 98/37/EC / Machinery Directive.

Table of Contents