Technical Specifications - SDMO R 340 U User And Maintenance Manual

Table of Contents

Advertisement

2.2.

Technical specifications

Range / Generating set type
Weights and Dimensions
Dimensions with standard tank
Dimensions with high autonomy tank
Output
Voltage
Hz
480/277 V
60
380/220 V
60
220/127 V
60
208/120 V
60
(1) ESP: Stand-by output available for emergency use under variable charge up to 200hrs per year as per lSO 8528-1, no
overload available under these service conditions.
(2) PRP: Main output available continuously under variable load for an unlimited time period per year as per ISO 8528-1, an
overload of 10% one hour every 12 hours is available, as per ISO3046-1.
Engine data
Manufacturer / model
Type
Cylinder configuration
Cubic capacity
Rotation speed
Max emergency/prime power at nominal speed
Adjustment type
Fuel consumption
110 % (emergency power)
100 % main power
75 % main power
50 % main power
Phase
Load factor
3
0.8
3
0.8
3
0.8
3
0.8
17/285
RENTAL POWER / R340U
Dimensions l x w x h:
4475 mm x 1410 mm x 2690 mm
Weight:
3830 kg dry weight 4300 kg in operating configuration
Hood:
M228C
Noise level:
80 dB à 1 m (0.70)
70 dB à 7 m (0.70)
Dimensions l x w x h:
4527 mm x 1410 mm x 2780 mm
Weight:
4520 kg dry weight 5888 kg in operating configuration
Hood:
M228C-DW
Noise level:
80 dB à 1 m (0.70)
70 dB à 7 m (0.70)
Max current (A)
Emergency power
Emergency
453
301.6 / 377
573
301.6 / 377
989
301.6 / 377
1046
301.6 / 377
VOLVO TAD941GE
Turbo
6 L
9.36 L
1800 Rpm
344 / 313 kW
Electrical
79.2 L/h
70.8 L/h
52.8 L/h
37.0 L/h
1
Prime power
kW / kVA
kW / kVA
274.2 / 342.7
274.2 / 342.7
274.2 / 342.7
274.2 / 342.7
2

Hide quick links: