Measuring Tools - Rotax 912 Series Maintenance Manual

Hide thumbs Also See for 912 Series:
Table of Contents

Advertisement

11.5) Measuring tools

Vernier callipers, dial gauge, micrometer, internal micrometer,
feeler gauge,
spring scale up to 50 kp (500 N).
Stroboscope: BOSCH
Multimeter:
Oscilloscope:TEKTRONIX
(optional)
WARNING:
Effectivity: 912 Series
AIRCRAFT ENGINES
MAINTENANCE MANUAL II
®
0 684 100 308 or equivalent.
Supply voltage 8 ÷ 15 V. Flash triggering by inductive pick-up. Flashing
frequency 4500 r.p.m.
FLUKE
®
series 70, series 80 or equivalent.
Electronic, 3 1/2 digits indication.
Current range 10 A.
Direct voltage range 200 V minimum.
Resistance range 200 Ω ÷ 2 MΩ
Accoustic continuity tester.
®
2225 or equivalent
2 channels
Analogous
Sensitivity 5 mV to 5V/div
Frequency limit 50 MHz
Using these instruments, observe the manufacturer's specifica-
tions.