Owden Cable, Rope Sheave And Spring For Wastegate Control - Rotax 912 Series Maintenance Manual

912/914 series
Hide thumbs Also See for 912 Series:
Table of Contents

Advertisement

3.6)
Bowden cable, rope sheave and spring for wastegate control (on the
914 Series)
See Fig. 78-9
3.6.1)
17
1
11
11
16
8
7
02618
Effectivity 912/914 Series
Edition 1 / Rev. 0
BRP-Rotax
Maintenance Manual
Disassembly
Remove tension spring (1) with a suitable tool and cut wire (2) of the
Bowden cable.
Loosen set screw of nipple (3) and pull Bowden cable out of the cable
retainer (4).
Do not lose the pressure spring (5) 5.5/1.2/16.9. Remove spring and
store in a safe place.
Remove cotter pin (6) and pin (7) from wastegate lever (8).
Now the Bowden cable can be pulled out from the conduit.
If required, remove rope sheave (9) after removal of the allen screw
(10) M5 x 20 along with lock washer and washer.
Fig. 78-9
1
6
7
14
15
15
6
3
4
5
18
12
2
10
9
13
78-00-00
page 19