2.2)
Rectifier regulator
Electronic full-wave rectifier regulator.
Type
14.2 V
Output voltage
Current limit:
Current limit
Max. 22 A.
Max. permissible component temperature:
Component tem-
perature
+80 °C (176 °F) (measured in area (1)).
NOTE:
See chap. 72-00-00 section: weight.
Weight
Connection
Graphic
Fig. 2
Effectivity: 912 Series
Edition 2/Rev. 0
BRP-Powertrain
INSTALLATION MANUAL
±
±
0.3 (from 1000
250 rpm).
The performance specifications are given for optimal
cooled components. If necessary, use a separate heat sink
for the rectifier regulator.
1
2
Part
1
Area component temperature
2
Description of connections:
G = yellow - from generator
R = red - to battery, positive terminal
B = battery positive terminal
L = warning lamp circuit
C = control or field circuit
G G R
B
L C
Function
08631
24-00-00
page 6