17.3) Technical data and connection of the electric components

17.3.1) Integrated generator

Cyl. 2
Cyl. 4
1
ge

17.3.2) Rectifier-regulator

Effectivity: 912 Series
Edition 1 / Rev. 0
INSTALLATION MANUAL
See Fig. 68
Feeding wires (1) from the generator to rectifier-regulator on left side
of ignition housing (see Fig. 68).
-
2 flexible cables, 1,5 mm
-
length approx. 660 mm (26 in.) starting from ignition housing
-
with on each plug socket 6,3 x 0,8 to DIN 46247
◆ NOTE:
approx. 250W AC output at 5800 (r.p.m.)
For DC output in connection with rectifier-regulator
see section 17.3.2.
Cyl. 1
Cyl. 3
02498
Fig. 68
ge
yellow
yellow
See Fig. 69/70.
-
type: electronic full-wave rectifier regulator
-
effective voltage:
-
current limit:
-
max. permissible
component temperature: +80 °C (176 °F)
(measured in area (1))
-
weight:
◆ NOTE:
The performance specifications are given for optimal
cooled components. If necessary, use a separate heat
sink for the rectifier regulator.
BRP-Rotax
2
yellow (in shielding metal braid)
14 ± 0,3 V (from 1000 ± 250 r.p.m.)
max. 22 A
see section 8.