Replacing The Failed Internal Hard Disk Unit - PRIMERGY BX620 S3 User Manual

Table of Contents

Advertisement

Chapter 7 Installing Internal Options
■ How to Remove the Internal Hard Disk Unit
1
Turn off the server blade.
→ "3.3 Turning off the Server" in "BX600 S2 Blade Server System Unit Hardware Guide"
2
Touch a metal part of the chassis to discharge static electricity.
3
Remove the internal hard disk unit.
While pressing the tab, open the cover (1), and pull out the internal hard disk unit (2).
To remove the internal hard disk unit, use both hands to pull it out.
4
Install a new internal hard disk unit or a dummy unit.
"7.7.3 How to Install the Internal Hard Disk Unit" (pg.201)

■ Replacing the Failed Internal Hard Disk Unit

When an array system (RAID1) is configured with this server, a failed hard disk unit can be replaced and
the restoration can be performed without turning off the server and peripheral devices (hot swappable/
hot pluggable).
For more details on the replacement procedure, refer to "Integrated Mirroring SAS User's Guide" in the
Array controller Document & Tool CD.
For more details on the array system, refer to "Integrated Mirroring SAS User's Guide".