6-10. JIB PUMP
REPLACEMENT
Aug. 2014
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move
the POWER switch to OFF and disconnect main
circuit breaker, or unplug cord at wall receptacle.
2. Remove the lower back shroud (See back shroud removal).
3. Remove blower (see blower removal sections).
4. Using an adjustable wrench, remove the flex line from the
elbow.
5. Loosen the hose clamp with a flat blade screw driver and
disconnect the hose.
6. Use a 3/8 socket or wrench and remove the four nuts and
washers from the pumps feet.
7. Pull the pump off of the studs.
8. Remove the wire nuts.
9. Wire the new pump into the existing wires.
10. Place the pump onto the studs. Be sure to have the shield
box in place on the studs before placing the pump onto
studs.
11. Tighten the pump nuts and washers onto the feet of the
pump.
12. Reconnect fittings.
13. Replace blower.
48
Model EEG-241, 242, 243, 244