Hot Swap Drive Troubleshooting (Model 3220); Hot Swap Drive Troubleshooting (Model 3220R) - Digital Equipment Digital Server 3220 Series System Reference Manual

Hide thumbs Also See for Digital Server 3220 Series:
Table of Contents

Advertisement

Hot Swap Drive Troubleshooting (Model 3220)

Problem
Drive fault LED lit.
Drive activity and fault
LEDs lit.
Drive fault LED flashing.

Hot Swap Drive Troubleshooting (Model 3220R)

Problem
Drive status LED lit.
Drive status and fault status
LEDs lit.
Fault status LED flashing.
Disk drive present LED off.
Possible Cause
Drive failed.
Drive is hung or has failed.
Drive is in recovery mode
or has failed and is spinning
down.
Possible Cause
Drive failed.
Drive is hung or has failed.
Drive is in recovery mode
or has failed and is spinning
down.
No drive installed or not
fully seated in the drive bay.
Troubleshooting
Action
Replace hot swap drive.
Replace hot swap drive.
Allow the drive array to build or fully
spin down.
Action
Replace hot swap drive.
Replace hot swap drive.
Allow drive array to build or fully
spin down.
Reseat the drive or make sure the
installed drive is fully seated in the
drive bay.
13-13