Operation
6. Continue to push the hose connections firmly
onto the auxiliary hydraulic connections until
they snap into place.
CAUTION
Route the hydraulic hoses so they do not get
pinched when the attachment is tilted forward
and back. Damaged or burst hydraulic hoses
could result.
IMPORTANT:
Always check hydraulic function of
the attachment before use, to make sure the
hydraulic hoses have not been installed in reverse.
NOTE:
Pressure build-up caused by heat in
hydraulic attachments left in direct sunlight can
make it difficult to connect the quick-couplers to
the fittings on the attachment.
Disconnecting Hydraulic Attachments
from the Auxiliary Hydraulics Circuit
1. Empty the attachment and lower it to the
ground.
2. Shut off the engine and turn off the ignition.
Remove the ignition key and take it with you.
3. Raise the safety bars/arm rests to apply the
parking brake.
4. Push on the hose connection locking rings until
the hose connections release.
918468/EP0313

Auxiliary Hydraulics Operation

Standard-Flow Auxiliary Hydraulics Control

The toggle and trigger switches (A and B, Fig. 67)
on the right joystick controls standard-flow
auxiliary hydraulics.
A
B
Fig. 67 – Auxiliary Flow Control (Regular-Flow)
Press the top (C) of toggle switch (A) to activate
auxiliary hydraulics flow in one direction. Flow
control is proportional: the flow rate increases as the
toggle switch is moved further. Release the switch to
stop the flow.
Press the bottom (D) of toggle switch (A) to activate
auxiliary hydraulics flow in the opposite direction.
Flow control is proportional: the flow rate increases
as the toggle switch is moved further. Release the
switch to stop the flow.
For continuous flow:
1. Move toggle switch (A) as far as it will go either
forward or back – depending upon what direc-
tion flow is required.
2. While holding the toggle switch (A) at the full
forward or full reverse position, press trigger
button (B). Release trigger button first (B), then
release toggle switch (A).
NOTE:
Standard flow auxiliary hydraulics
continuous flow can only be activated if toggle
switch (A) is held in either the FULL forward or
FULL reverse position.
To stop continuous standard-flow, press and release
trigger switch (B).