Maintenance
After Storage
1. Replace and re-connect the battery.
2. Perform all steps for returning the engine to
service according to long-term engine storage
section in the engine operation manual.
3. Check V-belt tension.
4. Check all fluid levels and top-off as necessary.
5. Start the engine. Observe all indicators. If all
indicators are functioning properly and reading
normally, move the machine outside.
6. When outside, park the machine and let the
engine idle for at least 5 minutes.
7. Shut off the engine and walk around machine.
Make a visual inspection looking for evidence of
leaks.
918468/EP0313
Air Conditioning Maintenance
Test air conditioning function weekly. Reduced air
conditioning function could indicate a low
refrigerant level. Low refrigerant or refrigerant leaks
can cause air conditioning compressor overheating
and failure.
IMPORTANT:
Air conditioning system should be
filled only by technicians trained in the air condition-
ing fill processes.
Air Conditioning Filters
Check the condition of the air conditioning filters
every 250 hours of use and replace if necessary.
NOTE:
Extreme or dusty/dirty conditions may
require more frequent maintenance.
Cab Air Filter
1. Slide the operator's seat as far forward as it will
go to provide access to the cab wall behind the
seat.
2. Remove fasteners (A, Fig. 121) securing filter
grilles (S) to the cab wall. Remove and discard
the old filter elements.
3. Insert new filter elements and secure with grilles
(S) and fasteners (A). Make sure the filter
elements are completed seated in the openings
and the grilles are firmly seated flush to the cab
wall.
A
Fig. 121 – Cab Air Filters
126
A
A
S
Printed in U.S.A.
A