Powering Attachments With Hydraulic Function; Connecting Hydraulic Attachments To The Auxiliary Hydraulic Circuits - Gehl RT175 Operator's Manual

Compact track loader
Hide thumbs Also See for RT175:
Table of Contents

Advertisement

1. Empty the attachment and drive to a open, level
area to disconnect the attachment.
2. Lower the attachment to the ground.
3. Place the attachment lock into the unlocked
position (Fig. 65):
• Power-A-Tach® system hitch – Press the
bottom of hitch lock switch (I) until safety
flags (H) have moved all the way in.
• Manual attachment hitch – move hitch lock
lever all the way to the right (G).
Power-A-Tach® Quick Attach System Hitch Disconnection
I
H
Manual Attachment Hitch Disconnection
K
G
Fig. 65 – Attachment Hitch – Unlocked
4. Lower the lift arm until tabs (J) on top of the
attachment plate disengage out of hooks (K) on
the back of the attachment.
5. Look behind you for bystanders and obstacles.
Drive straight back in reverse away from the
attachment.
Printed in U.S.A.
Powering Attachments with
Hydraulic Function
Hydraulically-powered attachments are powered
using the auxiliary hydraulics circuits.
Connecting Hydraulic Attachments to
the Auxiliary Hydraulic Circuits
IMPORTANT:
attachment hoses to the auxiliary circuits after the
attachment is secured to the hitch.
Disconnect hydraulically-powered attachment
hoses from the auxiliary circuits before removing
the attachment from the hitch.
K
NOTE:
for both the normal and the optional high-flow
auxiliary hydraulic circuits.
J
Fig. 66 – Auxiliary Hydraulic Circuit Connections
J
1. Empty the attachment and lower it to the
ground.
2. Shut off the engine and turn off the ignition.
Remove the ignition key and take it with you.
3. Raise the safety bars/arm rests to apply the
parking brake.
4. Clean the hydraulic connections on the hoses
and the connections.
5. Relieve the pressure in the standard auxiliary
hydraulics circuit by pushing the attachment
coupler firmly into the auxiliary coupler.
85
Connect hydraulically-powered
The connection procedure is the same
High-Flow
Connections
(Option)
Operation
Standard
Connections
918468/EP0313

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rt210

Table of Contents